Chinese Journal of Magnetic Resonance ›› 2024, Vol. 41 ›› Issue (3): 276-285.doi: 10.11938/cjmr20243103
• Articles • Previous Articles Next Articles
CHEN Qi1,2, LI Haidong1,2, FANG Yuan1, SHEN Luyang1, LIU Wuji1,2, LUO Ming1, LI Yecheng1,2, ZHANG Ming1,2, ZHAO Xiuchao1,2, SHI Lei1,2, ZHOU Qian1, HAN Yeqing1,2, ZHOU Xin1,2,*()
Received:
2024-03-23
Published:
2024-09-05
Online:
2024-04-09
Contact:
*Tel: 027-87198631, E-mail: xinzhou@wipm.ac.cn.
CLC Number:
CHEN Qi, LI Haidong, FANG Yuan, SHEN Luyang, LIU Wuji, LUO Ming, LI Yecheng, ZHANG Ming, ZHAO Xiuchao, SHI Lei, ZHOU Qian, HAN Yeqing, ZHOU Xin. Association of 129Xe Ventilation Functional MRI with Pulmonary Lesion Types[J]. Chinese Journal of Magnetic Resonance, 2024, 41(3): 276-285.
Table 1
Demographics, PFTs, respiratory questionnaire and 129Xe MRI results of volunteers
基本信息 | CT异常(n=123) | CT正常(n=20) |
---|---|---|
年龄 | 57.5 ± 12.7 | 43.3 ± 13.4 |
男性人数 | 79 (64.2%) | 13 (65.0%) |
BMI | 24.8 ± 3.4 | 24.3 ± 3.2 |
PFTs | ||
FEV1%pred | 105.0 ± 14.4 | 107.3 ± 12.8 |
FVC%pred | 107.3 ± 14.1 | 112.5 ± 13.3 |
FEV1/FVC%pred | 94.9 ± 6.0 | 95.2 ± 4.8 |
RV%pred | 86.7 ± 22.8 | 102.6 ± 20.2 |
TLC%pred | 89.9 ± 12.6 | 96.8 ± 8.8 |
RV/TLC%pred | 93.8 ± 18.5 | 104.8 ± 16.3 |
FRC%pred | 100.5 ± 22.1 | 112.7 ± 12.1 |
PEF%pred | 111.7 ± 22.0 | 99.0 ± 17.1 |
呼吸问卷 | ||
SGRQ评分 | 12.0 ± 13.7 | 8.8 ± 10.9 |
129Xe MRI | ||
全局VDP(%) | 4.6 ± 3.0 | 3.2 ± 1.6 |
Table 2
Lung lobe structure-function information
CT(0)-129Xe MRI(0) | CT(0)-129Xe MRI(1) | CT(1)-129Xe MRI(0) | CT(1)-129Xe MRI(1) | |
---|---|---|---|---|
RUL | 54(37.8%) | 16(11.1%) | 15(10.5%) | 58(40.6%) |
RML | 74(51.7%) | 13(9.1%) | 18(12.6%) | 38(26.6%) |
RLL | 43(30.0%) | 7(4.9%) | 32(22.4%) | 61(42.7%) |
LUL | 49(34.3%) | 32(22.3%) | 10(7.0%) | 52(36.4%) |
LLL | 53(37.1%) | 18(12.6%) | 21(14.7%) | 51(35.7%) |
总计 | 273(38.2%) | 86(12.0%) | 96(13.4%) | 260(36.4%) |
[1] | EMAMI K, KADLECEK S J, WOODBURN J M, et al. Improved technique for measurement of regional fractional ventilation by hyperpolarized 3He MRI[J]. Magn Reson Med, 2010, 63(1): 137-150. |
[2] | LOPES A J. Advances in spirometry testing for lung function analysis[J]. Expert Rev Respir Med, 2019, 13(6): 559-569. |
[3] | OGUMA T, HIRAI T, NIIMI A, et al. Limitations of airway dimension measurement on images obtained using multi-detector row computed tomography[J]. PLoS One, 2013, 8(10): e76381. |
[4] |
DE BACKER J W, VOS W G, VINCHURKAR S C, et al. Validation of computational fluid dynamics in CT-based airway models with SPECT/CT[J]. Radiology, 2010, 257(3): 854-862.
doi: 10.1148/radiol.10100322 pmid: 21084417 |
[5] | KERN A L, VOGEL-CLAUSSEN J. Hyperpolarized gas MRI in pulmonology[J]. Br J Radiol, 2018, 91(1084): 20170647. |
[6] | WANG G X, YANG H Y, LI J, et al. Overview and progress of X-nuclei magnetic resonance imaging in biomedical studies[J]. Magn Reson Lett, 2023, 3(4): 327-343. |
[7] | CHEN X M, ZHAO X C, SUN X P, et al. Study on the automatic accumulation-thawing device of hyperpolarized 129Xe[J]. Chinese J Magn Reson, 2022, 39(3): 316-326. |
陈小明, 赵修超, 孙献平, 等. 超极化129Xe自动收集-升华装置研究[J]. 波谱学杂志, 2022, 39(3): 316-326.
doi: 10.11938/cjmr20222998 |
|
[8] | DRIEHUYS B, MARTINEZ-JIMENEZ S, CLEVELAND Z I, et al. Chronic obstructive pulmonary disease: safety and tolerability of hyperpolarized 129Xe MR imaging in healthy volunteers and patients[J]. Radiology, 2012, 262(1): 279-289. |
[9] | SHUKLA Y, WHEATLEY A, KIRBY M, et al. Hyperpolarized 129Xe magnetic resonance imaging: tolerability in healthy volunteers and subjects with pulmonary disease[J]. Acad Radiol, 2012, 19(8): 941-951. |
[10] | MCINTOSH M J, KOONER H K, EDDY R L, et al. Asthma control, airway mucus, and 129Xe MRI ventilation after a single benralizumab dose[J]. Chest, 2022, 162(3): 520-533. |
[11] | KOONER H K, MCINTOSH M J, MATHESON A M, et al. Postacute COVID-19 Syndrome: 129Xe MRI Ventilation Defects and Respiratory Outcomes 1 Year Later[J]. Radiology, 2023, 307(2): e222557. |
[12] | LI H D, ZHAO X C, WANG Y J, et al. Damaged lung gas exchange function of discharged COVID-19 patients detected by hyperpolarized 129Xe MRI[J]. Sci Adv, 2021, 7(1): eabc8180. |
[13] |
ZHOU Q, RAO Q, LI H D, et al. Evaluation of injuries caused by coronavirus disease 2019 using multi-nuclei magnetic resonance imaging[J]. Magn Reson Lett, 2021, 1(1): 2-10.
doi: 10.1016/j.mrl.2021.100009 pmid: 35673615 |
[14] |
XIE H Y, ZHAO Z, ZHANG W J, et al. Quantitative analysis of lung function and airway remodeling using ventilation/perfusion single photon emission tomography/computed tomography and HRCT in patients with chronic obstructive pulmonary disease and asthma[J]. Ann Nucl Med, 2023, 37(9): 504-516.
doi: 10.1007/s12149-023-01848-7 pmid: 37268867 |
[15] | EIBSCHUTZ L S, RABIEE B, ASADOLLAHI S, et al. FDG-PET/CT of COVID-19 and Other Lung Infections[J]. Semin Nucl Med, 2022, 52(1): 61-70. |
[16] | MATIN T N, RAHMAN N, NICKOL A H, et al. Chronic obstructive pulmonary disease: lobar analysis with hyperpolarized 129Xe MR imaging[J]. Radiology, 2017, 282(3): 857-868. |
[17] | EDDY R L, SVENNINGSEN S, KIRBY M, et al. Is computed tomography airway count related to asthma severity and airway structure and function?[J]. Am J Respir Crit Care Med, 2020, 201(8): 923-933. |
[18] | FAIN S B, GONZALEZ-FERNANDEZ G, PETERSON E T, et al. Evaluation of structure-function relationships in asthma using multidetector CT and hyperpolarized 3He MRI[J]. Acad Radiol, 2008, 15(6): 753-762. |
[19] | AGUSTí A, CELLI B R, CRINER G J, et al. Global initiative for chronic obstructive lung disease 2023 report: GOLD executive summary[J]. Eur Respir J, 2023, 61(4): 2300239. |
[20] |
DE LANGE E E, ALTES T A, PATRIE J T, et al. Evaluation of asthma with hyperpolarized helium-3 MRI: correlation with clinical severity and spirometry[J]. Chest, 2006, 130(4): 1055-1062.
doi: 10.1378/chest.130.4.1055 pmid: 17035438 |
[21] | VIRGINCAR R S, CLEVELAND Z I, KAUSHIK S S, et al. Quantitative analysis of hyperpolarized 129Xe ventilation imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease[J]. NMR Biomed, 2013, 26(4): 424-435. |
[22] | CAREY K J, HOTVEDT P, MUMMY D G, et al. Comparison of hyperpolarized 3He-MRI, CT based parametric response mapping, and mucus scores in asthmatics[J]. Front Physiol, 2023, 14: 1178339. |
[23] | COCCONCELLI E, BERNARDINELLO N, GIRAUDO C, et al. Characteristics and prognostic factors of pulmonary fibrosis after COVID-19 pneumonia[J]. Front Med (Lausanne), 2021, 8: 823600. |
[24] | XIE R L, WANG Y, ZHAO Y N, et al. Lung nodule pre-diagnosis and insertion path planning for chest CT images[J]. BMC Med Imaging, 2023, 23(1): 22. |
[25] | DODD J D, LAVELLE L P, FABRE A, et al. Imaging in cystic fibrosis and non cystic fibrosis bronchiectasis[J]. Semin Resp Crit Care, 2015, 36(2): 194-206. |
[1] | GUO Xu, WANG Chenxu, ZHANG Xin, CHANG Yan, CUI Feng, GUO Qingqian, HU Tao, YANG Xiaodong. Semantic Audiovisual Single-trial Detection Based on the New Generation of Magnetoencephalography [J]. Chinese Journal of Magnetic Resonance, 2024, 41(3): 304-314. |
[2] | LUO Qingjin, WU Liangyong, WANG Yuting, YAN Haiyang, XIANG Yifeng, CHEN Siyu. Optimization Analysis and Experimental Verification of FID NMR Coil in Polarized 3He Systems [J]. Chinese Journal of Magnetic Resonance, 2024, 41(3): 266-275. |
[3] | YI Peng, CAO Li, HUANG Zhen, CHENG Xin, WANG Jiaxin, CHEN Li, CHEN Fang, BAO Qingjia, ZHANG Zhi, LIU Chaoyang. Development of Gradient Coils and 1H/13C Dual-resonance RF Coils for a Small-bore 5 T MRI System [J]. Chinese Journal of Magnetic Resonance, 2024, 41(3): 245-256. |
[4] | SHI Xing, ZHANG Yue, ZHANG Xiuli, WANG Cong. Stereochemical Research on Cembranes Diterpenoid Sinulariol Z Based on Residual Dipolar Couplings [J]. Chinese Journal of Magnetic Resonance, 2024, 41(3): 322-330. |
[5] | LI Mingdao, YAO Shouquan, XU Juncheng, LV Xinglong, HE Fengcheng, JIANG Yu. Design of the Handheld NMR Console [J]. Chinese Journal of Magnetic Resonance, 2024, 41(3): 257-265. |
[6] | WANG Xingle, SHAO Zhengze, DONG Hongchun, WEI Daxiu, CHEN Qun, YAO Yefeng. Studies on the 1H NMR Spectral Features of Hydrogen Molecules in the Interstices of SiO2 Particles [J]. Chinese Journal of Magnetic Resonance, 2024, 41(3): 315-321. |
[7] | YANG Liming, WANG Yuanjun. Research Progress of Denoising Algorithms for Diffusion Tensor Images [J]. Chinese Journal of Magnetic Resonance, 2024, 41(3): 341-361. |
[8] | SHEN Xueyuan, WANG Ruichen , QI Guodong, XU Jun, DENG Feng. Design of in situ Solid-state NMR Rotor Inserts and Their Application to Catalytic Reactions [J]. Chinese Journal of Magnetic Resonance, 0, (): 0-0. |
[9] | Luo Wenyou, Rong Xing. A W-band Electron Paramagnetic Resonance Probe based on Fabry-Perot Cavity [J]. Chinese Journal of Magnetic Resonance, 0, (): 0-0. |
[10] | LI Zhengzhe, GUO Liang, REN Xuhu. A Passive Shimming Method for Halbach Magnet Based on Numerical Optimization Algorithm [J]. Chinese Journal of Magnetic Resonance, 2024, 41(2): 128-138. |
[11] | ZHU Xiaofeng, ZHAO Zhihong, TAN Rui, ZHOU Long, WANG Yichuan, LIU Wenjing, ZHANG Minghui, LIU Huabing. Water Migration Characteristics of Pinus Sylvestris During the Drying Process Studied by Single-sided Nuclear Magnetic Resonance [J]. Chinese Journal of Magnetic Resonance, 2024, 41(2): 173-183. |
[12] | FENG Yuan, QIU Suhao, YAN Fuhua, YANG Guang-Zhong. Magnetic Resonance Elastography and Its Application in Brain Diseases [J]. Chinese Journal of Magnetic Resonance, 2024, 41(2): 209-223. |
[13] | ZHANG Haowei, WANG Yuncheng, LIU Ying. Brain Age Assessment of Patients with Major Depressive Disorder Based on Convolutional Neural Network [J]. Chinese Journal of Magnetic Resonance, 2024, 41(2): 139-150. |
[14] | LIU Tingwei, PENG Bowen, XU Yajie, WANG Ya, WANG Feng, YU Peng, YANG Xiaodong. A Design of Active Shimming Power Supply for Magnetic Resonance Spectrometers [J]. Chinese Journal of Magnetic Resonance, 2024, 41(2): 117-127. |
[15] | Dai Junlong, He Cong, Wu Jie, Bian Yun. Pancreatic Cystic Neoplasms Segmentation Network Combining Dual Decoding and Global Attention Upsampling Modules [J]. Chinese Journal of Magnetic Resonance, 2024, 41(2): 151-161. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||