[1] HAACKE E M, BROWN R W, THOMPSON M R,et al. Magnetic resonance imaging:Physical principles and sequence design[M]. New Jersey:John Wiley & Sons, 2014.
[2] 周康荣, 陈祖望. 体部磁共振成像[M]. 上海:上海医科大学出版社, 2000.
[3] VOVK U, PERNUS F, LIKAR B. A review of methods for correction of intensity inhomogeneity in MRI[J]. IEEE T Med Imaging, 2007, 26(3):405-421.
[4] DAWANT B M, ZIJDENBOS A P, MARGOLIN R A. Correction of intensity variations in MR images for computer-aided tissue classification[J]. IEEE T Med Imaging, 1993, 12(4):770-781.
[5] ERNST T, KREIS R, ROSS B D. Absolute quantitation of water and metabolites in the human brain. I. compartments and water[J]. J Magn Reson, 1993, 102(1):1-8.
[6] PRUESSMANN K P, WEIGER M, SCHEIDEGGER M B, et al. SENSE:sensitivity encoding for fast MRI[J]. Magn Reson Med, 1999, 42(5):952-962.
[7] MIHARA H, IRIGUCHI N, UENO S. A method of RF inhomogeneity correction in MR imaging[J]. Magn Reson Mater Phys, 1998, 7(2):115-120.
[8] HOU Z J. A review on MR image intensity inhomogeneity correction[J]. Int J Biomed Imaging, 2006, 2006(49515):1-11.
[9] BALAFAR M A, RAMLI A R, MASHOHOR S. A new method for MR grayscale inhomogeneity correction[J]. ArtifIntell Rev, 2010, 34(2):195-204.
[10] SLED J G, ZIJDENBOS A P, EVANS A C. A nonparametric method for automatic correction of intensity nonuniformity in MRI data[J]. IEEE T Med Imaging, 1998, 17(1):87-97.
[11] ZHUGE Y, UDUPA J K, LIU J, et al. Image background inhomogeneity correction in MRI via intensity standardization[J]. Comput Med Imag Grap, 2009, 33(1):7-16.
[12] GARCIA-SEBASTIAN M, FERN-NDEZ E, GRANA M, et al. A parametric gradient descent MRI intensity inhomogeneity correction algorithm[J]. Pattern Recogn Lett, 2007, 28(13):1657-1666.
[13] MAKSIMOVIC R, STANNKOVIC S, MILOVANOVIC D, et al. Computed tomography image analyzer:Segmentation applying active contour models——"snakes"[J]. Stud Health Technol Inform, 1999, 68:395-399.
[14] ZHANG S, SHE L H, WANG H Y, et al. Brain MR image segmentation and bias field estimation using coherent local and non-local spatial constraints[C]. Guiyang:Proceedings of the 25th Chinese Control and Decision Conference (CCDC), 2013.
[15] LI C M, XU C Y, ANDERSON A W, et al. MRI tissue classification and bias field estimation based on coherent local intensity clustering:A unified energy minimization framework[J]. Inf Process Med Imaging, 2009, 21(2):88-99.
[16] LI C M, HUANG R, DING Z H, et al. A level set method for image segmentation in the presence of intensity inhomogeneities with application to MRI[J]. IEEE T Image Process, 2011, 20(7):2007-2016.
[17] OSHER S, SETHIAN J A. Fronts propagating with curvature-dependent speed:Algorithms based on Hamilton-Jacobi formulations[J]. J Comput Phys, 1988, 79(1):12-49.
[18] BREGMAN L M. The relaxation method of finding the common point of convex sets and its application to the solution of problems in convex programming[J]. USSR Comput Math Math Phys, 1967, 7:200-217.
[19] OSHER S, BURGER M, GOLDFARB D, et al. An iterative regularization method for total variation-based image restoration[J]. Multiscale Model Sim, 2006, 4(2):460-489.
[20] YIN W T, OSHER S, GOLDFARB D, et al. Bregman iterative algorithms for l1-minimization with applications to compressed sensing[J]. SIAM J Imaging Sci, 2008, 1(1):143-168.
[21] GOLDSTEIN T, OSHER S. The split bregman method for l1-regularized problems[J]. Siam J Imaging Sci, 2009, 2(2):323-343.
[22] SMITH D S, GORE J C, YANKEELOV T E, et al. Real-time compressive sensing MRI reconstruction using GPU computing and split Bregman methods[J]. Int J Biomed Imaging, 2012, 1-6.
[23] YANG Y Y, LI C M, KAO C Y, et al. Split Bregman method for minimization of region-scalable fitting energy for image segmentation[M]. Berlin:Springer Berlin Heidelberg, 2010.
[24] GOLDSTEIN T, BRESSON X, OSHER S. Geometric applications of the split Bregman method:Segmentation and surface reconstruction[J]. J Sci Comput, 2010, 45(1):272-293.
[25] YANG Y Y, ZHAO Y, WU B Y. Split Bregman method for minimization of fast multiphase image segmentation model for inhomogeneous images[J]. J Optimiz Theory App, 2014, 166(1):285-305.
[26] LIKAR B, VIERGEVER M A, PERNUS F. Retrospective correction of MR intensity inhomogeneity by information minimization[J]. IEEE T Med Imaging, 2001, 20(12):1398-1410.
[27] LI C M, XU C Y, GUI C F, et al. Level set evolution without re-initialization:A new variational formulation[J]. CVPR'05, 2005. doi:10.1109/CVPR.2005.213.
[28] 杨云云. 基于Split Bregman方法的快速图像分割模型的研究[D]. 哈尔滨:哈尔滨工业大学, 2012.
[29] BRESSON X, ESEDOGLU S, VANDERGHEYNST P, et al. Fast global minimization of the active contour/snake model[J]. J Math Imaging Vis, 2007, 28(2):151-167. |