波谱学杂志 ›› 2019, Vol. 36 ›› Issue (2): 195-207.doi: 10.11938/cjmr20182692

• 研究论文 • 上一篇    下一篇

CEST成像不同量化方式在急性帕金森氏病小鼠模型研究中的应用比较

魏国境, 易佩伟, 陶泉, 冯衍秋   

  1. 南方医科大学 生物医学工程学院, 广东省医学图像处理重点实验室, 广东 广州 510515
  • 收稿日期:2018-11-24 发布日期:2019-01-16
  • 通讯作者: 冯衍秋 Tel:020-61648294, E-mail:foree@163.com E-mail:foree@163.com
  • 基金资助:
    the National Natural Science Foundation of China (61671228, 61728107).

Comparisons of Different CEST Quantification Metrics Applied in Acute Parkinson's Disease Mouse Model

WEI Guo-jing, YI Pei-wei, TAO Quan, FENG Yan-qiu   

  1. Guangdong Key Laboratory of Medical Images Processing, School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China
  • Received:2018-11-24 Published:2019-01-16
  • Supported by:
    the National Natural Science Foundation of China (61671228, 61728107).

摘要: 本文通过比较7 T场强下化学交换饱和转移(chemical exchange saturation transfer,CEST)成像技术不同量化方式在急性帕金森氏病小鼠模型研究中的应用效果,探讨了客观无创的帕金森氏病研究方案.使用Bruker PharmaScan 7 T小动物磁共振成像(Magnetic Resonance Imaging,MRI)扫描仪,对经1-甲基-4-苯基-1,2,3,6-四氢吡啶(1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine,MPTP)急性造模前及造模后第3、10天的小鼠黑质、皮层及海马进行扫描,计算弛豫时间T1T2MTRasym(magnetization transfer ratio based on asymmetry analysis)、MTRrex(magnetization transfer ratio yielding Rex)、AREX(apparent exchange-dependent relaxation)及5池拟合后的胺峰面积Areaamine、酰胺峰面积Areaamide.结果显示仅黑质中融合了倒Z谱分析和5池洛仑兹拟合所得的量化指标MTRrex、AREXAreaamine在造模后显著减小,与黑质免疫组化结果一致,而T1T2以及基于Z谱非对称性分析的MTRasym未见统计学差异,这表明此量化方式消除了直接饱和效应及磁化转移效应的影响,准确性上要优于Z谱非对称分析法,更能正确地提示帕金森氏病黑质的变化.

关键词: 磁共振成像(MRI), 化学交换饱和转移(CEST), 洛仑兹拟合, 倒Z谱分析法, 1-甲基-4-苯基-1,2,3,6-四氢吡啶(MPTP)

Abstract: Non-invasive and quantifiable diagnosis of Parkinson's disease (PD) is an ongoing challenge for researchers. In this study, we compared two different chemical exchange saturation transfer (CEST) imaging quantification metrics in substantia nigra (SN), cortex and hippocampus of acute 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-induced PD mice at three different time points including before MPTP administration, and the 3rd and 10th day after MPTP administration. Area of amine (Areaamine), magnetization transfer ratio yielding Rex (MTRrex) and apparent exchange-dependent relaxation (AREX) in SN derived from 5-pool Lorentzian fitting and inverse Z-spectrum analysis showed a statistically significant decrease after successful modeling, while there were no significant alterations in T1, T2, and magnetization transfer ratio based on asymmetry analysis (MTRasym). The results suggested that the former quantification is superior to that based on Z-spectrum asymmetry in vivo due to the exclusion of direct saturation (DS) and magnetic transfer (MT) effects and may reflect the destroying SN of PD.

Key words: magnetic resonance imaging (MRI), chemical exchange saturation transfer (CEST), Lorentzian fitting, inverse Zspectrum analysis, 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)

中图分类号: