Chinese Journal of Magnetic Resonance ›› 2018, Vol. 35 ›› Issue (1): 128-132.doi: 10.11938/cjmr20172579

Previous Articles    

A Large-Size Slotted Tube Microwave Cavity for High-Performance Rubidium Atomic Frequency Standard

LV Jian-feng1,2, HAO Qiang1,2, WANG Peng-fei1, ZHAO Feng1, MEI Gang-hua1   

  1. 1. CAS Key Laboratory of Atomic Frequency Standards(Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences), Wuhan 430071, China;
    2. University of Chinese Academy of Sciences, Beijing 100049, China
  • Received:2017-05-08 Online:2018-03-05 Published:2018-03-05

Abstract: The frequency stability of a passive rubidium atomic frequency standard (RAFS) largely depends on the performance of the microwave cavity used in the physics package. In this paper, a large-size slotted tube microwave cavity with an inner diameter of 40 mm, as well as the physics package based on this cavity, were designed and built. Theoretical calculations and experimental results showed that the magnetic lines inside this cavity were highly parallel to the quantization axis. The frequency discrimination slope and the shot noise of the physics package were measured. The results showed that the cavity could be used to realize an RAFS with frequency stability of 2×10-13τ-1/2.

Key words: rubidium atomic frequency standard, slotted-tube microwave cavity, orientation factor, frequency stability