摘要: 介绍了一种用于主动减小NQR探头恢复时间的Q值变换电路,它利用MOEFET控制变Q电路与探头电路的耦合,并通过变压器增加与电感线圈串联的阻抗值以达到改变Q值的目的. 此电路不会产生新的振铃也不会对接收NQR的分辨率造成损失. 实验结果表明,电路能有效缩短探头的恢复时间,同时还可以提高信噪比.

关键词: 探头, NQR, 变Q电路, 恢复时间

Abstract: An active Q-switching circuit using a transformer is described for reducing the recovery time of NQR probes. A MOSFET was used to control the coupling and decoupling states of the Q-switching circuit to the probe so that it did not operate during the reception of NQR signals. The performance of the circuits was demonstrated by experimental results. It was shown that the circuit did not create new ringing, and caused no loss in sensitivity.

Key words: NQR, probe, Q-switching, recovery time