一种带外部锁场通道的小型化核磁共振射频探头设计
|
王峰 1,2,刘庭伟 1,2,徐雅洁 2,*( ),郁朋 2,3,王亚 2,彭博文 2,4,杨晓冬 2,#( )
|
A Miniaturised NMR RF Probe Design with External Field-locking Channel
|
WANG Feng 1,2,LIU Tingwei 1,2,XU Yajie 2,*( ),YU Peng 2,3,WANG Ya 2,PENG Bowen 2,4,YANG Xiaodong 2,#( )
|
|
图6. 氢、氟线圈的S参数测量结果.(a)氢线圈S11为-34.8 dB,氟线圈S11为-32.5 dB;(b)两线圈之间的隔离度S21在-30 dB左右
|
Fig. 6. S-parameter measurements for hydrogen and fluorine coils. (a) S11 -34.8 dB for hydrogen coil and S11 -32.5 dB for fluorine coil; (b) Isolation between the two coils S21 is around -30 dB
|
|
|
|
|