基于PCAU-Net的快速多通道磁共振成像方法
|
施伟成,金朝阳,叶铮
|
Fast Multi-channel Magnetic Resonance Imaging Based on PCAU-Net
|
SHI Weicheng,JIN Zhaoyang,YE Zheng
|
|
表4 基于随机采样,在不同加速因子下,不同算法重建图像的定量指标的平均值
|
Table 4 The average values of quantitative indicators of reconstructed images with different algorithms under different acceleration factors based on random sampling
|
|
量化指标 | SPIRiT | PCU-Net | PCAU-Net | TRE | R = 2.5 | 1.10×10-3 | 7.8081×10-4 | 7.7575×10-4 | | R = 3.3 | 1.10×10-3 | 8.3336×10-4 | 8.1667×10-4 | | R = 4.0 | 1.50×10-3 | 8.7133×10-4 | 8.9446×10-4 | | R = 4.6 | 1.40×10-3 | 9.4146×10-4 | 9.0757×10-4 | | R = 5.0 | 1.90×10-3 | 9.8781×10-4 | 9.9610×10-4 | SSIM | R = 2.5 | 0.9629 | 0.9656 | 0.9727 | | R = 3.3 | 0.9588 | 0.9642 | 0.9694 | | R = 4.0 | 0.9327 | 0.9632 | 0.9720 | | R = 4.6 | 0.9419 | 0.9596 | 0.9593 | | R = 5.0 | 0.9051 | 0.9536 | 0.9660 | PSNR | R = 2.5 | 33.2773 | 33.2802 | 33.9417 | | R = 3.3 | 32.7259 | 32.9076 | 33.5339 | | R = 4.0 | 29.0483 | 32.7743 | 33.5606 | | R = 4.6 | 27.8330 | 32.3175 | 32.4758 | | R = 5.0 | 26.6143 | 31.8950 | 32.1532 |
|
|
|